EasyManua.ls Logo

Siemens M20 Terminal

Siemens M20 Terminal
234 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AT command interface
Version 8 dated 15.03.00 48
Siemens Information and Communication Products
A
AT+DS V.42bis data compression control
Test command
AT+DS=?
Response
+DS: (list of supported <p0>s), (list of supported <n>s), (list of supported <p1>s), (list of suppor-
ted <p2>s) OK
Parameter
see set command
Read command
AT+DS?
Response
+DR: <p0>,<n>,<p1>,<p2> OK
Parameter
see set command
Set command
AT+DS=[<p0>[,<
n>[,<p1>[,<p2>]]]]
Response
This parameter setting determines the possible data compression mode by TA at the compression
negotiation with the remote TA after call setup.
Note1
: only for data call
Note2
: GSM transmits the data transparent. The remote TA may support this compression.
OK
Parameter
Note: see also ITU V.42bis
<p0> 0 NONE
1 transmit only
2 receive only
3
both directions, but allow negotiation
<n> 0
allow negotiation of p0 down
1 do not allow negotiation of p0 – disconnect on difference
<p1> 512
-1024 dictionary size
Note:
default determined by manufacturer
<p2> 6
-64 maximum string size
Reference
V.25ter
Note
Functionality depends on network
AT+GCAP Request complete TA capabilities list
Test command
AT+GCAP=?
Response
OK
Parameter
Execute command
AT+GCAP
Response
TA reports a list of additional capabilities.
+GCAP: <name>
OK
Parameter
<name> e.g.: +CGSM, +FCLASS, +DS, +DR
Reference
V.25ter
Note

Table of Contents

Related product manuals