DKFD.PS.027.W3.02
SITRANS F M MAGFLO
Siemens Flow Instruments
range of electromagnetic
flowmeters
2
MAG 5000 MAG 6000 MAG 3000
Ex-d
Outputs 1 current output 1 current output 1 current output
1digital output 1digital output 1 frequency/pulse output
1 relay output 1 relay output 1 relay output
Flow direction Uni/bidirectional Uni/bidirectional Uni/bidirectional
Communication Optional Add-on modules
HART
HART
Display 3 lines 3 lines 2 lines
20 characters 20 characters 16 characters
(optional without display) (optional without display)
Meter uncertainty ±0,5% o.r. ±0,25% o.r. ±0,25% o.r.
Enclosure IP 67, IP 20 IP 67, IP 20 IP 65, IP 67
Custody transfer PTB PTB
approval (cold water) OIML R75
OIML R117
Ex-version [EEx ia] IIC [EEx ia/ib] IIB EEx de [ia/ib] IIB T6
Safety barrier [EEx ia] IIC
Power supply 12-24 V a.c./d.c. 12-24 V a.c./d.c. 24 V a.c./d.c.
115-230 V a.c. 115-230 V a.c.
Batch No Yes No
MAG 1100 MAG 1100 MAG 3100 MAG 3100 W MAG 5100 W
FOOD
Size [mm] DN 6-100 DN 10-100 DN 15-2000 DN 25-1200 DN 25-1200
Connection Flangeless Weld-in adapter, Flange Flange Flange
(Sandwich design) clamp adapter,
thread adapter
Pressure [bar] Max. 40 Max. 40 Max. 100 Max. 40 Max. 40
Temperature [
°°
°°
°C] −20 to 200 −30 to 150 −40 to180 −10 to 95 −5 to 90
Liner Ceramic (Al
2
O
3
) Ceramic (Al
2
O
3
) Neoprene, EPDM, Neoprene and DN 25-40 &
PFA PFA Teflon (PTFE), EPDM DN 350-1200
Polyurethane, hard elastomer
Ebonite, DN 50-300
Linatex
composite elastomer
Electrodes Platinum Platinum AISI 316 Ti, AISI 316 Ti, AISI 316 Ti,
Hastelloy C276 Hastelloy Hastelloy C, PE electrodes PE electrodes
Platinum/Iridium,
Titanium,
Tantalum,
PE electrodes
Enclosure IP 67 IP 67 IP 67/IP 68 IP 67/IP 68 IP 67/IP 68
Ex-version EEx ia/ib IIB T4-T6 EEx ia/ib IIB T4-T6
EEx ia/e IIC T3-T6