42
SITRANS F M MAGFLO
DKFD.PS.027.W3.02
6. Installation of signal converter
Installation of signal conv.
6.2.3
Remote installation -
Wall mounting
MAG 6000
Mount wall bracket on a wall or into the back of
a panel.
Mount wall bracket on a vertical or horizontal
pipe using an ordinary hose clip or a duct strap.
Vertical pipe mounting
Horizontal pipe mounting
Take the SENSORPROM
®
memory unit from
the sensor. Mount the SENSORPROM
®
unit in
the wall mounting unit as shown. The text on the
SENSORPROM
®
unit must face towards the
wall bracket.
Mount an earth wire between PE on connection
board and bottom of connection box.