10 DKFD.PS.027.W3.02
2. Technical data
Technical data
SITRANS F M MAGFLO
Type Sensor with flanges Sensor with flanges Sensor with flanges
Nominal size
mm
DN 15-2000 DN 15-2000 / 15-300 DN 25-1200
Temperature of medium Temperature classification
Liner:
T3 + T4 T5 T6
Neoprene (standard) 0 to 70°C 0 to 70°C 0 to 70°C 0 to 70°C 0 to 70°C
EPDM
1
) −10 to 95°C −10 to 95°C −10 to 90°C −10-75°C −10 to 95°C
Linatex
rubber −40 to 70°C
2
) −20 to 70°C −20 to 70°C −20 to 70°C
Ebonite
1
) 0 to 95°C 0 to 95°C 0 to 90°C 0 to 75°C
PTFE −20 to 100°C −20 to 100°C −20 to 90°C −20 to 75°C
PTFE high temperature −20 to 180°C
Ambient temperature
Remote signal converter −40°C to 100°C −20°C to 50°C −40°C to 100°C
Compact signal converter −20°C to 50°C −20°C to 50°C −20°C to 50°C
Operating pressure
3
)
[[
[[
[abs.bar
]]
]]
]
Liner:
Neoprene 0.01 to 100 bar 0.01 to 100 bar 0.01 to 40 bar
EPDM 0.01 to 40 bar 0.01 to 40 bar 0.01 to 40 bar
Linatex
0.01 to 40 bar 0.01 to 40 bar
Ebonite 0.01 to 100 bar 0.01 to 100 bar
PTFE teflon:
DN 15 to 600 Max. 100°C: 0.3 to 50 bar 0.3 to 40 bar
DN 15 to 300 Max. 180°C: 0.6 to 50 bar
Excitation frequency DN 15 - 65: 12.5 Hz DN 15 - 65: 6.25 Hz All sizes 3.125 Hz
DN 80 - 150: 6.25 Hz DN 80/100: 3.125 Hz
DN 200 - 1200: 3.125 Hz DN 125 - 300: 1.5625 Hz
DN 1400 - 2000: 1.5625 Hz DN 350 - 1200: 3.125 Hz
Enclosure rating
Standard
IP 67 to EN 60529 (NEMA 4x) (1 m w.g for 30 min.)
Option
IP 68 to EN 60529 (NEMA 6) (10 m w.g. cont.)
Cable entries 4 Pg 13.5
Mechanical load 18-1000 Hz random, 3.17 G rms in all directions to EN 60068-2-36
Test pressure 1.5 × PN
Conforms to PED, LVT, EMC PED - 97/23EC, LVD - 73/23 EEC + amendment 93/68/EEC, EMC - 89/336 EEX
2.3 Sensor MAG 3100, MAG 3100 Ex and MAG 3100 W
MAG 3100 MAG 3100 Ex / Ex-d MAG 3100 W
1
) With WRC (Water Research Council, UK) approval
2
) For temperature below −20°C AISI 304 or 316 flanges must be used
3
) Maximum operating pressure decreases with increasing operating temperature and with stainless steel flanges
MAG 3100, MAG 3100 Ex and MAG 3100 W