SITRANS F M MAGFLO
8. Commissioning
Commissioning
Menu detail
Limit/direction
Limit switches are available for both digital as well as relay output.
Direction mode: 1 set point at 0% flow; hysteresis 5%.
If 2 set points must activate 2 separate outputs, a single set point has to be selected individually for
digital as well as relay outputs.
Batch
(MAG 6000 only)
(Possible through relay and
digital output)
8.4.4
Relay outputs
Cleaning
8.4.5
External input
Batch control is available on MAG 6000 only.
The relay output must always be used to operate the cleaning unit when a cleaning unit has been
installed together with the signal converter. The relay output cannot be used for other purposes.