EasyManuals Logo

Siemens MCP 398C Equipment Manual

Siemens MCP 398C
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #113 background imageLoading...
Page #113 background image
Internal power supply (P24OUT):
The internal power supply for the digital inputs (X111, X222, X333: Pin 2) is derived from the
general power supply of module X1, pin 2 (P24).
Technical data:
Table 9-24 Electrical speci󹪝cation of the digital inputs:
Digital inputs min. max. Nominal
High-level voltage (U
H
) 15 V 30 V 24 V
Input current I
IN
at V
H
2 mA 15 mA -
Low-level voltage (U
L
) -3 V 5 V 0 V
Signal delay time T
PHL
0.5 ms 3 ms -
Connectable components
9.2 PP 72/48D PN
NCU 7x0.3B PN
Equipment Manual, 10/2020, 6FC5397-1EP40-6BA1 113