International English 5 System Parameters
MICROMASTER 440 Operating instructions
6SE6400-5CA00-0BP0
61
Par. No. Parametername Default Acc WS QC
r0062 CO: Freq. setpoint - 3 - -
r0063 CO: Act. frequency - 3 - -
r0064 CO: Dev. frequency controller - 3 - -
r0065 CO: Slip frequency - 3 - -
r0066 CO: Act. output frequency - 3 - -
r0067 CO: Act. output current limit - 3 - -
r0068 CO: Output current - 3 - -
r0071 CO: Max. output voltage - 3 - -
r0072 CO: Act. output voltage - 3 - -
r0075 CO: Current setpoint Isd - 3 - -
r0076 CO: Act. current Isd - 3 - -
r0077 CO: Current setpoint Isq - 3 - -
r0078 CO: Act. current Isq - 3 - -
r0079 CO: Torque setpoint (total) - 3 - -
r0086 CO: Act. active current - 3 - -
P0095[10] CI: Display PZD signals 0:0 3 CT N
r0096[10] PZD signals - 3 - -
r1084 Max. frequency setpoint - 3 - -
P1300[3] Control mode 0 2 CT Q
P1310[3] Continuous boost 50.0 2 CUT N
P1311[3] Acceleration boost 0.0 2 CUT N
P1312[3] Starting boost 0.0 2 CUT N
P1316[3] Boost end frequency 20.0 3 CUT N
P1320[3] Programmable V/f freq. coord. 1 0.00 3 CT N
P1321[3] Programmable V/f volt. coord. 1 0.0 3 CUT N
P1322[3] Programmable V/f freq. coord. 2 0.00 3 CT N
P1323[3] Programmable V/f volt. coord. 2 0.0 3 CUT N
P1324[3] Programmable V/f freq. coord. 3 0.00 3 CT N
P1325[3] Programmable V/f volt. coord. 3 0.0 3 CUT N
P1330[3] CI: Voltage setpoint 0:0 3 T N
P1333[3] Start frequency for FCC 10.0 3 CUT N
P1335[3] Slip compensation 0.0 2 CUT N
P1336[3] Slip limit 250 2 CUT N
r1337 CO: V/f slip frequency - 3 - -
P1338[3] Resonance damping gain V/f 0.00 3 CUT N
P1340[3] Imax controller prop. gain 0.000 3 CUT N
P1341[3] Imax controller integral time 0.300 3 CUT N
r1343 CO: Imax controller freq. output - 3 - -
r1344 CO: Imax controller volt. output - 3 - -
P1345[3] Imax controller prop. gain 0.250 3 CUT N
P1346[3] Imax controller integral time 0.300 3 CUT N
P1350[3] Voltage soft start 0 3 CUT N
P1400[3] Configuration of speed control 1 3 CUT N
r1407 CO/BO: Status 2 of motor control - 3 - -
r1438 CO: Freq. setpoint to controller - 3 - -