5 System Parameters International English
MICROMASTER 440 Operating instructions
62 6SE6400-5CA00-0BP0
Par. No. Parametername Default Acc WS QC
P1452[3] Filter time for act.speed (SLVC) 4 3 CUT N
P1470[3] Gain speed controller (SLVC) 3.0 2 CUT N
P1472[3] Integral time n-ctrl. (SLVC) 400 2 CUT N
P1477[3] BI: Set integrator of n-ctrl. 0:0 3 CUT N
P1478[3] CI: Set integrator value n-ctrl. 0:0 3 UT N
r1482 CO: Integral output of n-ctrl. - 3 - -
P1488[3] Droop input source 0 3 CUT N
P1489[3] Droop scaling 0.05 3 CUT N
r1490 CO: Droop frequency - 3 - -
P1492[3] Enable droop 0 3 CUT N
P1496[3] Scaling accel. precontrol 0.0 3 CUT N
P1499[3] Scaling accel. torque control 100.0 3 CUT N
P1500[3] Selection of torque setpoint 0 2 CT Q
P1501[3] BI: Change to torque control 0:0 3 CT N
P1503[3] CI: Torque setpoint 0:0 3 T N
r1508 CO: Torque setpoint - 2 - -
P1511[3] CI: Additional torque setpoint 0:0 3 T N
r1515 CO: Additional torque setpoint - 2 - -
r1518 CO: Acceleration torque - 3 - -
P1520[3] CO: Upper torque limit 5.13 2 CUT N
P1521[3] CO: Lower torque limit -5.13 2 CUT N
P1522[3] CI: Upper torque limit 1520:0 3 T N
P1523[3] CI: Lower torque limit 1521:0 3 T N
P1525[3] Scaling lower torque limit 100.0 3 CUT N
r1526 CO: Upper torque limitation - 3 - -
r1527 CO: Lower torque limitation - 3 - -
P1530[3] Motoring power limitation 0.75 2 CUT N
P1531[3] Regenerative power limitation -0.75 2 CUT N
r1538 CO: Upper torque limit (total) - 2 - -
r1539 CO: Lower torque limit (total) - 2 - -
P1570[3] CO: Fixed value flux setpoint 110.0 2 CUT N
P1574[3] Dynamic voltage headroom 10 3 CUT N
P1580[3] Efficiency optimization 0 2 CUT N
P1582[3] Smooth time for flux setpoint 15 3 CUT N
P1596[3] Int. time field weak. controller 50 3 CUT N
r1598 CO: Flux setpoint (total) - 3 - -
P1610[3] Continuous torque boost (SLVC) 50.0 2 CUT N
P1611[3] Acc. torque boost (SLVC) 0.0 2 CUT N
P1740 Gain for oscillation damping 0.000 3 CUT N
P1750[3] Control word of motor model 0 3 CUT N
r1751 Status word of motor model - 3 - -
r1770 CO: Prop. output of n-adaption - 3 - -
r1771 CO: Int. output of n-adaption - 3 - -
P1780[3] Control word of Rs/Rr-adaption 3 3 CUT N
r1782 Output of Rs-adaptation - 3 - -
r1787 Output of Xm-adaption - 3 - -
http://nicontrols.com