3 Configuration and commissioning of the Service Bridge
Service Bridge Setup and Configuration
Entry ID: 109747975, V1.4, 05/2019
28
Siemens AG 2019 All rights reserved
Activating Management ACL
The Management ACL function can be activated after the ES has been entered
into the Management ACL list.
1. Activate the "Management ACL" check box (1).
2. Click the "Set Values" button (2) to confirm the settings.
2
1
CAUTION
Activate the management ACL function only after you have entered the
engineering station in the list. Otherwise, you may block the access to the
WBM of the Service Bridge.
If this happens, it will only be possible to deactivate the filter via the serial
interface using CLI, or to reset the Service Bridge to the factory settings
with the "SELECT/SET" button after the system has been de-energized.