5 Firewall configuration using the example of a SCALANCE SC632-2C
Service Bridge Setup and Configuration
Entry ID: 109747975, V1.4, 05/2019
55
Siemens AG 2019 All rights reserved
33. Click the "Set Values" button (5) to confirm the settings.
Note
Depending on the applications used (e.g. PRONETA), additional IP rules may be
required for automatically assigned IP addresses.
By default, PRONETA temporarily uses the highest free IP address in the subnet
during the network scan. In the IP address range 192.168.11.0/24, this is
192.168.11.254 if not used.
So that PRONETA can access all data during network scanning, another IP rule
is necessary that allows access for this IP address.
1
2
3
4
5