5-18
5.10 End-of-Profile Conditions
5.10.1
Different
conditions cause profiles to terminate execution. Y
ou can
determine the condition when the profile terminated by checking the
following:
WX2
(WY6)+
V12
for
Clamp Close status bits
V13
for
Inject status bits
V14
for
Pack and Hold status bits
V15
for
Plasticate status bits
V16
for
Clamp Open status bits
T
able 5-1 shows the types of conditions causing termination for the different
profiles.
T
able 5-1
Locations for Conditions Causing Pr
ofile T
ermination
Profile Conditions Causing Termination of Profile
Max
T
ime
Min Position
Time Position Pressure Emergency
Clamp
Close
(WY6)+V12
(WY5)+V2 (WY5)+V15
to
(WY5)+V24
WY8
= 0
or
WY7
1
121
Inject
(WY6)+V13
(WY5)+V46 (WY5)+V59
to
(WY5)+V68
(WY5)+V47
and
(WY5)+V48
WY8 = 0
or
WY7
1
121
Pack/Hold
(WY6)+V14
(WY5)+V90 (WY5)+V103
to
(WY5)+V112
(WY5)+V91
and
(WY5)+V92
WY8 = 0
or
WY7
1
121
Plasticate
(WY6)+V15
(WY5)+V134 (WY5)+V147
to
(WY5)+V156
WY8 = 0
or
WY7
1
121
Clamp
Open
(WY6)+V16
(WY5)+V178 (WY5)+V191
to
(WY5)+V200
WY8 = 0
or
WY7
1
121
To
disable
transition
conditions:
To
disable transition
conditions, load
32767 in location
identified in
T
able 2-9
T
o disable transition
conditions, load
32767 in location
identified in
T
able 2-9
Not Applicable Not Applicable
T
o disable transition
conditions, load
32767 in location
identified in
T
able 2-9
Not Applicable
Checking
End-of-Profile
Condition