Software Interface
2-31
T
able 2-9
Upload
T
able Memory Map
Real-time
Pr
ocess V
ariables, Cycle Status, SPC/SQC Data, Discr
ete Status
Location Description Range
(WY6) 1* Actual loop calculation time 0—32767 microseconds
2 Clamp position feedback (CH9) 0—32000
3 Clamp velocity calculated by module
4 Clamp hydraulic flow output (CH1)
5 Clamp hydraulic pressure feedback (CH4)
6 Clamp pressure output signal (CH2)
7 Ram position feedback (CH7)
8 Ram velocity calculated by module
9 Ram hydraulic flow output (CH5)
10 Ram hydraulic pressure feedback (CH8)
↓
11 Ram hydraulic pressure output (CH6) 0—32000
12 Clamp close status bits
16 bits
13 Inject status bits
14 Pack and hold status bits
15 Plasticate status bits
↓
16 Clamp open status bits
16 bits
17 Inject final ram position 0—32000
18 Inject final calculated velocity
19 Inject final ram pressure
↓
20 Inject final cavity pressure 0—32000
21 Accumulated inject profile time 0—655.35 seconds
22 Pack and hold final ram position 0—32000
23 Pack and hold final calculated velocity
24 Pack and hold final ram pressure
↓
25 Pack and hold final cavity pressure 0—32000
26 Accumulated pack and hold profile time 0—655.35 seconds
27 Accumulated clamp close profile time
28 Accumulated plasticate profile time
↓
29 Accumulated clamp open profile time 0—655.35 seconds
* This value is updated only when profile is running. During other times the old value is left in place until
next profile.