Software Interface
2-20
Block Read Data: PLC Module (continued)
Bit 9
Reverse Acting for V
elocity Loop
116
[.... .... 0... ....] No
reverse acting
[.... .... 1... ....] Reverse
acting
Bit
10
Reverse Acting for Pressure Loop
116
[.... .... .0.. ....] No
reverse acting
[.... .... .1.. ....] Reverse
acting
Bits 11–16
116
[.... .... ..xx xxxx] Reserved
T
able 2-6
contains the step data entry format and T
able 2-7 contains the
pack and hold step data entry format.
T
able 2-6
Step Data Entry For
mat*
Position Velocity Pressure
Current/Starting
Position
28,000
Step 1
20,000 16,000 8,000
These values are in
effect until Step 1
position is reached
Step 2
16,000 8,000 4,000
The values are in
effect until Step 2
position is reached
*All
profiles except Pack and Hold
T
able 2-7
Pack
and Hold Step Data Entry For
mat
Cumulative
Time
Velocity Pressure
Current/Starting
T
ime (elapsed)
0
Step 1
300 16,000 8,000
(Step 1 = 3 s)
Step 2*
500 12,000 6,000
(Step 2 = 2 s)
*Time
for Step 2 = 500 – 300 = 200 or 2 s)
Constant 14
(continued)