Selected Functions
5-3
5.1.2
Each
profile can be programmed with as few as one or as many as ten steps.
W
ord WX1, module cycle status, is continuously updated with the profile
number and step number within that profile. See T
able 2-1 for WX1 details.
Step numbers, while the plasticate cycle is running by itself, are
reported as 401, 402, 403, etc., as in normal operation.
Step numbers, while the clamp opening cycle is running by itself, are
reported as 501, 502, 503, etc., as in normal operation.
While the plasticate and clamp open profiles are running
simultaneously (overlapping cycles), step numbers are reported in the
format
1xxyy
, where
1
indicates the overlapping operation,
xx
indicates
the plasticate step being run, and
yy
indicates the clamp open step
being run.
For example, WX1 = 10305 indicates overlapping operation with plasticate
profile in step 3 and clamp closing profile in step 5.
Step Numbers