Software Interface
2-10
PLC Output Words: PLC Data → Module (continued)
A
non-zero value in WY8 implies the functions identified in T
able 2-5.
T
able 2-5
Cycle Initiation Codes and Mode Select
(16-Bit Word)
Cycle Initiation Codes
Bit 1(MSB)
Bit 16(LSB)
and Mode Select
[1... .... .... ....] Clamp
close
[.1.. .... .... ....] Inject
[..1. .... .... ....] Pack
and hold
[...1 .... .... ....] Plasticate
[.... 1... .... ....] Clamp
open
[.... .1.. .... ....] Overlapping
cycles
Clamp
Close Setpoints:
[.... ..1. .... ....] Open
loop velocity
[.... ...1 .... ....] Open
loop pressure
Inject
Setpoints:
[.... .... 1... ....] Open
loop velocity
[.... .... .1.. ....] Open
loop pressure
Pack
and Hold Setpoints:
[.... .... ..1. ....] Open
loop ram velocity
[.... .... ...1 ....] Open
loop hydraulic pressure
Plasticate
Setpoints:
[.... .... .... 1...] Open
ram velocity
[.... .... .... .1..]
Open
loop hydraulic pressure
(back pressure)
Clamp
Open Setpoints:
[.... .... .... ..1.] Open
loop velocity
[.... .... .... ...1] Open
loop pressure