Software Interface
2-5
2.3 PLC Input Words: Module Data → PLC
2.3.1
The
module-cycle-status word continuously reports both the profile and the
step that the module is currently executing to the PLC. See T
able 2-1. For
example, WX1 = 305 means the module is currently executing Step 5 of
Pack and Hold.
T
able 2-1
WX1 = Module Cycle Status
Function
Code (integer)
Function
0 Module
initialized or not in run mode
101
Step 1
Clamp close profile
↓ ↓↓
110
Step 10
Clamp close profile
111
Clamp closure complete
201
Step 1 Injection profile
↓ ↓↓
210
Step 10
Injection profile
211
Injection complete
301
Step 1 Pack and hold profile
↓ ↓↓
310
Step 10
Pack and hold profile
311
Pack and hold complete
401
Step 1
Plasticate profile
↓ ↓↓
410
Step 10
Plasticate profile
411
Plasticate complete
501
Step 1
Clamp open profile
↓ ↓↓
510
Step 10
Clamp open profile
511
Clamp open complete
*10101
Step 1
Plasticate and clamp open
profiles (overlapping cycles on)
↓ ↓↓
*11010
Step 10
Plasticate and clamp open
profiles (overlapping cycles on)
Overla
in
c
cles on
Plasticate profile step
Clamp open profile step
*
WX1 = Module
Cycle Status