Four
high-speed analog outputs
Clamp hydraulic flow
Clamp hydraulic pressure
Injection ram hydraulic flow
Injection ram hydraulic pressure
V
oltage ranges: 0 to +10 V
, or 0 to –10 V
; 0 to +5 V
, or 0 to –5 V
12-bit resolution, 0.25% accuracy
5 mA output current
Five high-speed analog inputs
Clamp position
Clamp hydraulic pressure
Ram position
Ram hydraulic pressure
Cavity pressure
V
oltage range: 0 to +10 V
; 0 to +5 V
12-bit resolution, 0.1% accuracy
Differential inputs with
±
25 VDC, ACpk
common mode input range, 60 db 60 Hz rejection
and 400 k
common-mode/800 k
differential
input impedance typical
Outputs and inputs synchronized to loop processing
User programmable from less than 2 ms to 32.767 ms
Uses 400 V
-memory locations for profile data to/from PLC making all data
available to other modules, operator interfaces, and network devices
PLC control bits for:
Cycle boundary (transitions)
Profile error reporting
Block transfer via special function integrated circuit
Run/program and module good LED
Agency Approvals: U.L.
, CSA
listing