Software Interface
2-6
PLC Input Words: Module Data → PLC (continued)
2.3.2
The
cycle-complete-code word immediately reports the completion of each
cycle to the PLC. See T
able 2-2. For example, WX2 = binary value 0000 0000
0001 0000 means that the Clamp Open profile just completed.
T
able 2-2
WX2 = Cycle Complete Codes
(16-Bit Word)
Bit 1(MSB)
Bit 16(LSB)
Cycle Complete Code
[.... .... .... ...1] Clamp
closure complete
[.... .... .... ..1.] Injection
complete
[.... .... .... .1..] Pack
and hold complete
[.... .... .... 1...] Plasticate
cycle complete
[.... .... ...1 ....] Clamp
opening complete
[.... .... ..1. ....] Overlapping
cycle complete
[xxxx xxxx xx.. ....] Reserved
NOTE:
See real-time process status words (V12–V16 in upload table) for bits
that indicate type of completion.
WX2 = Cycle