Software Interface
2-32
Block Write Data: Module → PLC (continued)
T
able 2-9
Upload
T
able Memory Map (continued)
Real-time Process Variables, Cycle Status, SPC/SQC Data, Discrete Status
Location Description Range
(WY6+29) 30 Accumulated inject fill time 0—655.35 seconds
31 Accumulated pack and hold time 0—655.35 seconds
32 Peak inject cavity pressure 0—32000
33 Peak pack and hold cavity pressure
↓
34 Cavity pressure feedback (CH3) 0—32000
35 Profile indicator for SPC/SQC
100, 200, 300, 400, or 500 (integer)**
36 Step 1 average of 10 velocity inputs* 0—32000
37
38
39
40
41
42
43
44
↓↓
45 Step 10 average of 10 velocity inputs 0—32000
46 Step 1 average of 10 pressure inputs* 0—32000
47
48
49
50
51
52
53
54
↓↓
55 Step 10 average of 10 pressure inputs 0—32000
56 Discrete outputs, see Chapter 4
57 Adjusted Cushion Value 0—32000
58 Plasticate Adjusted Cushion Value 0—32000
59 Future Use
↓↓
100 Future use
* The
value contained in each of these words is an average of the ten most recent values read in. V
alues are updated only
at the end of the cycle.
**
100 = clamp close; 200 = inject; 300 = pack and hold; 400 = plasticate; 500 = clamp open. Clamp open will not be reported
in overlap mode.