EasyManua.ls Logo

Siemens SIMATIC 505 - Page 51

Siemens SIMATIC 505
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Software Interface
2-28
Block Read Data: PLC Module (continued)
T
able 2-8
Download
T
able Memory Map (continued)
Scaling
Constants and Discrete Outputs
Location Description Range
WY5+225 226 Clamp
close positive scale (future)
0—32000
227
Clamp close negative scale (future
0—32000
228
Injection positive scale
0—32000
229
Injection negative scale
0—32000
230
Pack and hold positive scale
0—32000
231
Pack and hold negative scale
0—32000
232
Plasticate positive scale
0—32000
233
Plasticate negative scale
0—32000
234
Clamp open positive scale (future)
0—32000
235
Clamp open negative scale (future)
0—32000
236
Discrete outputs, see Chapter 4
255
284
Reserved
300
The features above are applicable only to Machine Configuration 3 in
injection, pack and hold, and plasticate profiles, and work only on the
pressure loop mode. A zero value in any of these locations defaults to one.
For example, if the injection pressure loop calculates an output value of
32000, but V228 = 10, then the actual output is 32000/10 = 3200 or 1 volt.
T
able 2-8
Download T
able Memory Map (continued)
Update to a PLC Program
Location Description Range
WX4 256 Channel
number
1—9 (default value = 3)
The value in download table location 256 is the same as the associated value
in the upload table, except it is potentially updated at a faster rate.

Table of Contents

Other manuals for Siemens SIMATIC 505

Related product manuals