Installing and connecting the device   
3.2 Installing the device 
  SIMATIC IPC PX-39A 
40  Operating Instructions, 08/2022, A5E51699601-AA 
 
Degree of protection for overall device  
If you are fastening the device via a VESA adapter, degree of protection IP65 of the device is 
lost. 
Spray and water jets as well as penetrating substances can then damage the device. 
 
Dimensioning of the VESA adapter 
When selecting the VESA adapter, make sure that it is designed for at least four times the 
 
The device must be mounted securely 
Inadequately dimensioned fastening material may cause the device to fall down. Serious 
bodily injury may result. 
Make sure that fasteners are adequately dimensioned during installation of the device. 
Make sure to consider the weight of the device and the forces acting on the device when 
dimensioning the fasteners. This applies in particular to dynamic load of the device. All 
fasteners including mounting surfaces, support arm systems, and fastening elements such 
as screws must be able to carry at least four times the weight of the device.  
Observe any further statutory specifications applying at the location of use of the device and 
further applicable regulations with regard to the fastening of the device. 
Procedure 
1.  Attach the VESA adapter 100 x 100 mm to the marked locations. 
2.  To do this, use M4x10 screws with property class 8.8 and tighten these with a torque of 3 
Nm.