Technical specifications
8.4 Electromagnetic compatibility
SIMATIC IPC PX-39A
86 Operating Instructions, 08/2022, A5E51699601-AA
8.4 Electromagnetic compatibility
See the note in "Applicability of technical specifications (Page 82)".
EN 61000-6-4, CAN/CSA CISPR32 class A; KS C 9832, FCC class A
EN 61000-6-1; EN 61000-6-2; KS C 9835
Interference immunity on the sup-
ply cables
± 2 kV according to IEC 61000-4-4; burst
± 1 kV according to IEC 61000-4-5; symmetrical surge
± 2 kV according to IEC 61000-4-5; asymmetrical surge
Noise immunity on signal lines
± 1 kV acc. to IEC 61000-4-4; Burst; Length < 30 m
± 2 kV acc. to IEC 61000-4-4; Burst; Length > 30 m
± 2 kV acc. to IEC 61000-4-5; Surge; Length > 30 m
Immunity to electrostatic dis-
charge
± 6 kV contact discharge in accordance with IEC 61000-4-2
± 8 kV air discharge in accordance with IEC 61000-4-2
Immunity to RF interference
• 10 V/m 80 MHz – 2.7 GHz,
80% AM to IEC 61000-4-3
• 3 V/m 2.7 – 6 GHz,
80% AM to IEC 61000-4-3
• 10 V 10 KHz – 80 MHz,
Immunity to magnetic fields
100 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8)