Technical specifications 
  8.9 Technical specifications of the interfaces 
SIMATIC IPC PX-39A 
Operating Instructions, 08/2022, A5E51699601-AA 
91 
8.9  Technical specifications of the interfaces 
Observe the information in "Applicability of technical specifications (Page 82)" and use only 
original connections of the I/O to be connected. 
 
2 x connection of DisplayPort monitor 
4 × USB 3.2 Gen 2 type A, high current, backward compatible 
2
4 × Ethernet interface (RJ45), 10/100/1000 Mbps 
•  1 x Ethernet 1: Intel® Jacksonville i219-LM; iAMT-capable 
3, 4
 
•  1 x Ethernet 2: Intel® Springville i210-IT 
•  2 x Ethernet 3, 4: Intel® EC 1000S 
Wake on LAN, Remote Boot and the following Teaming modes are sup-
ported 
5
:  
•  Adapter Fault Tolerance (AFT) 
•  Adaptive Load Balancing (ALB) 
•  IEEE 802.3ad Dynamic Link Aggregation (DLA) 
•  Static Link Aggregation (SLA) 
•  Switch Fault Tolerance (SFT) 
RS232, 115 kbps max., 9-pin SUB-D, male 
Free slot for PCIe expansion cards (see Bus board (Page 109)) 
  An analog monitor can be used with an adapter cable (optional). 
  For unambiguous labeling, the Ethernet interfaces are numbered on the enclosure. The numbering 
by the operating system can differ. 
  No teaming with iAMT 
  When using iAMT, the X1 P1 interface must be used to connect to remote maintenance. 
5
  Only possible with ports X1 P1 and X2 P1