53
Commissioning the device
4
4.1
General information on commissioning
CAUTION
Danger of burns
The surface of the device can reach temperatures of over 70 °C. Any unprotected contact
may cause burns.
Avoid direct contact during operation of the device. Touch the device only with appropriate
protective gloves.
Note
Windows Embedded Standard 7
Read the EWF and FBWF information
Two
configurable write filters (Enhanced Write Filter and File Based Write Filter) are
provided with Windows
Embedded Standard. Read the EWF/FBWF information if you
activate and use them, otherwise you may experience data loss.
Note
Configuring memory cards in the device
Memory cards used in a device need to be configured on that device. Memory cards
configured on other devices will not boot as the drive parameters will be different.
Requirement
The device is connected to the power supply.
The protective conductor is connected.
The connection cables are plugged in correctly.
The following hardware is available for initial commissioning:
One USB keyboard
One USB mouse
A monitor/display