Technical specifications
9.4 Technical specifications
SIMATIC IPC277D
Operating Instructions, 12/2016, A5E03409486-AE
123
9.4.2
Environmental conditions
Climatic ambient conditions
Permitted mounting positions see section "Preparing for installation"
Temperature, tested in accordance with IEC 60068-2-1, IEC 60068-2-2
Temperature gradient in operation
Max. 10 °C/h, no condensation
Ambient temperature in operation 7", 9" and 12" 15" 19"
When installed vertically in horizontal format
When installed inclined, inclination vertical
installation, inclination < ± 45 °
When installed vertically in horizontal format
0 ... 50 °C
0 ... 50 °C
0 ... 45 °C
0 ... 50 °C
0 ... 45 °C
0 ... 40 °C
0 ... 45 °C
0 ... 45 °C
0 ... 40 °C
Temperature during storage/transport
Storage/transport, gradient
-20 to +60 °C
Max. 20 °C/h, no condensation
Relative humidity, tested in accordance with IEC 60068-2-78, IEC 60068-2-30
Operation
Storage/transport
5 … 85 % at 30 °C, no condensation
5 … 95 % at 25 °C, no condensation
Air pressure, in accordance with IEC 60068-2-13
Operation
Storage/transport
1080 to 795 hPa,
corresponds to an elevation of -1000 to 2000 m
1080 to 660 hPa,
corresponds to an elevation of -1000 to 3500 m
Mechanical ambient conditions
Vibration, tested according to DIN IEC 60068-2-6
Operation 5 Hz to 8.4 Hz: 3.5 mm
8.4 … 200 Hz: 9.8 m/s
2
Storage/transport 5 to 9 Hz: 3.5 mm
9 to 500 Hz: 9.8 m/s
2
Shock resistance, tested in accordance with IEC 60068-2-27, IEC 60068-2-29
Operation
Storage/transport
50 m/s
2
, 30 ms
250 m/s
2
, 6 ms