Operating the device
5.6 Remote maintenance of the device
86 Operating Instructions, 01/2021, A5E43920357-AA
5.6.2 Remote maintenance with iAMT
5.6.2.1 Enable Intel® AMT control on the device
To make use of "Intel® Active Management Technology ", proceed as follows:
Note the information on the device requirements for Intel® AMT. (Page 85)
First, enable the Intel® AMT functions (Page 86).
Then configure the Intel® AMT functions. (Page 87)
Note
You can
find information on the firmware settings in the user manual (UM) for the SMS-
W480 motherboard, see "
Important instructions and manuals for operating the device
(Page 11)".
5.6.2.2 Activate Intel® AMT
1. Switch on the device or restart it.
2. Immediately after turning on the device, as soon as the message "Press <DEL> or
<ESC> to enter setup" appears, press and hold the <Del> or <Esc> button.
The firmware user interface opens. Here you have the following keys available for
navigation:
Action
Key
Select entry (then confirm selection)
Arrow keys on the keyboard
Confirm selection <Enter> key
Back to previous window
<Esc> key
3. Select "Advanced" > "AMT Configuration".
4. Assign the "Enabled" value to the firmware setting "AMT BIOS Features".
5. Press the button <F4> (Save & Exit) and confirm the subsequent dialogue with <Y>.
6. Switch off the device and then configure the Intel® AMT functions (Page 87).