List of Operations S5-115F Manual
for organization blocks (OB)
for program blocks (PB)
for function blocks (FB)
for sequence blocks (SB)
Function
Execution time
in µsec.
CPU
942F
I Q F T C 321
Ope-
ration
(STL)
1 RLO-depend.?
2 RLO affected?
3 RLO reloaded?
Operands
Formal operand
Formal operand
Start timer (formal operand) with the value stored in ACCUM 1
as stored On-delay or increment a counter (formal operand)
Start timer (formal operand) with the value stored in ACCUM 1
as Off-delay or decrement a counter (formal operand)
Load and Transfer Operations
L=
L
LC=
Formal operand
N N N 127 *
BS N N N 66
Formal operand
N N N 121 *
Load the value of the formal operand into ACCUM 1
(Data type: BY, W)
Load a word from the system data area into ACCUM 1
Load the value of the formal operand in BCD into ACCUM 1
LW=
T=
Formal operand
126N N N
N N N 128 *
Load the bit pattern of a formal operand into ACCUM 1
(parameter type: D; data type: KF, FH, KM; KY, KS, KT, KC)
Transfer the contents of ACCUM 1 to the formal operand
(data type: BY, W)
Formal operand
Timer and Counter Operations
FR
FR=
SP=
SE=
SEC=
Y N Y 83
Formal operand
Y N Y 121 *
Enable timer/counter for cold restart.
If RLO = 1,
”FR T” restarts the timer, and
”FR C” sets, increments or decrements the counter
Enable formal operand (timer/counter) for cold restart.
(For detailed description see ”FR” operation)
Formal operand
Y N Y 121 *
Formal operand
Y N Y 121 *
Start timer (formal operand) as pulse with the value stored in
ACCUM 1.
Start timer (formal operand) as On-delay with the value stored
in ACCUM 1.
Formal operand
121 *Y N Y
Start timer (formal operand) with the value stored in ACCUM 1
as extended pulse or set counter (formal operand) with the
count specified.
121 *YY N
SSU=
121 *YNY
SFD=
* Plus execution time of the substituted operation
A-12
EWA 4NEB 811 6149-02

Table of Contents

Other manuals for Siemens SIMATIC S5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S5 and is the answer not in the manual?

Siemens SIMATIC S5 Specifications

General IconGeneral
Product type designationSIMATIC S5
Programming languageSTEP 5
Digital inputsVaries by model
Digital outputsVaries by model
Analog inputsVaries by model
Analog outputsVaries by model
Supply voltage24V DC
CPU TypeVaries by model
MemoryVaries by model
Digital I/OVaries by model
Analog I/OVaries by model
CommunicationPROFIBUS
Operating Temperature0°C to 60°C
Relative Humidity5% to 95% (non-condensing)