EasyManua.ls Logo

Siemens SIMATIC S7 - Memoryreset Method

Siemens SIMATIC S7
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIMATIC Automation Tool API for .NET framework
6.9 The ICPU interface
SIMATIC Automation Tool V2.1 user guide
Manual, V2.1.1 07/2016, A5E33042676-AC
105
6.9.3.6
MemoryReset method
Return type
Method name
Result
MemoryReset
Parameters
Name
Data type
Parameter type
Description
password
EncryptedString
In This method opens a legitimized connec-
tion to the device. Therefore a password
may be required
This method performs a memory reset on the CPU.
The following example searches the
IProfinetDeviceCollection for a CPU at a specific IP
address, and calls
MemoryReset for that CPU.
uint targetIPAddress = 0xC0A80001; // 192.168.0.1
IProfinetDeviceCollection devices = new IProfinetDeviceCollection();
Result retVal = myNetwork.ScanNetworkDevices(out devices);
if (retVal.Succeeded)
{
IProfinetDevice dev = devices.FindDeviceByIP(targetIPAddress);
if (dev != null)
{
ICPU devAsCpu = dev as ICPU;
if (devAsCpu != null)
{
retVal = devAsCpu.MemoryReset(new EncryptedString(""));
}
}
}