EasyManuals Logo

Siemens SIMODRIVE 611-D Installation Guide

Siemens SIMODRIVE 611-D
189 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #159 background imageLoading...
Page #159 background image
5 PLC Interface 11.92
5.3.6 Data transfer PLC/NC (DB 36)
5.3.6 Data transfer PLC/NC (DB 36)
1
DL 0
Value 1-
Value 3
Number
format
Access
disabled
Data
transfer
ended
Data
transfer
assigned
Data
transfer
busy
Fifo
full
Data
transfer
requested
2
DR 0
Value 1-
Value 3
Number
format
Access
disabled
Data
transfer
ended
Data
transfer
assigned
Data
transfer
busy
Fifo
full
Data
transfer
requested
3
DL 1
Value 1-
Value 3
Number
format
Access
disabled
Data
transfer
ended
Data
transfer
assigned
Data
transfer
busy
Fifo
full
Data
transfer
requested
4
DR 1
Value 1-
Value 3
Number
format
Access
disabled
Data
transfer
ended
Data
transfer
assigned
Data
transfer
busy
Fifo
full
Data
transfer
requested
5
DL 2
Value 1-
Value 3
Number
format
Access
disabled
Data
transfer
ended
Data
transfer
assigned
Data
transfer
busy
Fifo
full
Data
transfer
requested
Status data transfer
Error
7 6 5 4 3 2 1 0
Bit No.
Byte
No.
15 14 13 12 11 10 9 8
Number
inter-
face
byte
62
DR 30
Value 1-
Value 3
Number
format
Access
disabled
Data
transfer
ended
Data
transfer
assigned
Data
transfer
busy
Fifo
full
Data
transfer
requested
63
DL 31
Value 1-
Value 3
Number
format
Access
disabled
Data
transfer
ended
Data
transfer
assigned
Data
transfer
busy
Fifo
full
Data
transfer
requested
64
DR 31
Value 1-
Value 3
Number
format
Access
disabled
Data
transfer
ended
Data
transfer
assigned
Data
transfer
busy
Fifo
full
Data
transfer
requested
Error
Error
Error
Error
Error
Error
Error
65
DL 32
Value 1-
Value 3
Number
format
Access
disabled
Data
transfer
ended
Data
transfer
assigned
Data
transfer
busy
Fifo
full
Data
transfer
requested
Data transfer alarm-controlled
Error
7 6 5 4 3 2 1 0
Bit No.
Byte
No.
15 14 13 12 11 10 9 8
Number
inter-
face
byte
Notes:
1) If the PLC goes into stop on account of a parameter error, the number of the interface
byte is stored in the High byte of ACCU 2.
2) If several jobs are entered in the buffer for data transfer, a job with the number 65 is
processed before the others.
3) Data transfer is via function macro FB61 (Read) or FB62 (Write).
5–42
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60
SINUMERIK 840C (IA)

Table of Contents

Other manuals for Siemens SIMODRIVE 611-D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMODRIVE 611-D and is the answer not in the manual?

Siemens SIMODRIVE 611-D Specifications

General IconGeneral
BrandSiemens
ModelSIMODRIVE 611-D
CategoryControl Unit
LanguageEnglish

Related product manuals