09.95 1 NC/Drive Machine Data
1.4 Spindle-specific values (max. 6 spindles)
D e s i g n a t i o n
MD
No.
Standard
value
Maximum
input value
Reference
system
Input
unit
435* Gain factor for M19
gear stage 1
1666 10000
80 000
5)
-- 0.01 s
-1
436* - // - gear stage 2 1666 10000
80 000
5)
-- 0.01 s
-1
437* - // - gear stage 3 1666 10000
80 000
5)
-- 0.01 s
-1
438* - // - gear stage 4 1666 10000
80 000
5)
-- 0.01 s
-1
439* - // - gear stage 5 1666 10000
80 000
5)
-- 0.01 s
-1
440* - // - gear stage 6 1666 10000
80 000
5)
-- 0.01 s
-1
441* - // - gear stage 7 1666 10000
80 000
5)
-- 0.01 s
-1
442* - // - gear stage 8 1666 10000
80 000
5)
-- 0.01 s
-1
443* Position limit for M19 2000 720000 MS units
444* Tolerance of spindle speed 10 100 -- %
445* Tolerance max. spindle speed 10 100 -- %
446* Tolerance zero speed 100 10 000
4)
16000
-- 0.01 %
447* Switch-off delay controller
enable
1000 16000 -- ms
448* Lowest set spindle speed 3 16000 -- rev/min
1)
449* Desired speed 50 99999 -- rev/min
1)
450* Set oscillation speed 2)
3)
50
50
1000
10000
-- 0.01 % of max.
motor speed
451* Max. spindle speed 4000 99999 -- rev/min
1)
452* Spindle position with ext. M19 0 35999 -- 0.01 degree
453* Mode group 1 2
6
4)
--
455* u: Pulses variable increment
weighting
32 65000
99999999
3)
-- --
_____
1) If MD 520* bit 3=1, input resolution is 0.1 rev/min
2) Up to SW 2
3) SW 3 and higher
4) SW 4 and higher
5) SW 5 and higher
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60 1–15
SINUMERIK 840C (IA)