EasyManua.ls Logo

Siemens SIMODRIVE 611-D - Page 77

Siemens SIMODRIVE 611-D
189 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
09.95 1 NC/Drive Machine Data
1.11.3 611D drive machine data FDD/MSD (as from SW 4)
D e s i g n a t i o n
MD
No.
Standard
value
Maximum input
value
Reference
system
Input
unit
1103 Motor rated current 0.0 500.0 A
1104 Maximum motor current 0.0 500.0 A
1105 Reduction of maximum motor
current
100 100 %
1106 Power section code number 0000 FFFF Hex
1107 Transistor limit current power
section
200.0 500.0 A
1108 Thermal limit current power
section
200.0 500.0 A
1109 Limit current power section S6 200.0 500.0 A
1111 Rated current power section 200.0 500.0 A
1112 Number of pole pairs motor 0 6
1113 Torque constant 0.0 5.0 Nm/A
1114 Voltage constant 0.0 300.0 V
1115 Armature resistance 0.0 20.0
1116 Armature inductance 0.0 100.0 mH
1117 Motor moment of inertia 0.0 32.0 kgm
2
1118 Motor zero-speed current 0.0 500.0 A
1119 Inductance of series reactor 10.0 65.0 -- mH
1120 P gain current controller 2 000.0 10 000.0 V/A
1121 Reset time current controller 0.0 8 000.0 µs
1124 Symmetrizing reference model
current control loop
0.5 1.0
1125 Ramp-up time 1 in V/Hz
operation (from SW 5)
5.0 100.0 -- s
1126 Ramp-up time 2 in V/Hz
operation (from SW 5)
5.0 100.0 -- s
1127 Voltage if Hz = 0 V/Hz
operation (from SW 5)
2.0 10.0 V
1129 cos power factor
(from SW 5)
0.8 1.0 -- --
1130 Motor rated power 0.0 1 500.0 kW
1132 Motor rated voltage 0.0 5 000.0 V
1134 Motor rated frequency 0.0 3 000.0 Hz
1135 Motor no-load voltage 0.0 500.0 V
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60 1–67