EasyManua.ls Logo

Siemens SIMOTICS L-1FN3 - Inspection and Maintenance

Siemens SIMOTICS L-1FN3
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.2 Inspection and maintenance
Performing maintenance work on the motor
Note
It is essential that you observe the safety information provided in this documentation.
As a result of their inherent principle of operation, linear motors are always wear-free.
To ensure that the motor functions properly and remains free of wear, the following
maintenance work needs to be carried out:
Regularly check that the traversing paths are free
Regularly clean the motor space and remove foreign bodies (e.g. chips)
Regularly check the condition of the motor components.
Check the current consumption in the de󹪝ned test cycle (compare with values of the
reference travel)
Intervals between maintenance
Since operating conditions di󹪜er greatly, it is not possible to specify intervals between
maintenance work.
Indications that maintenance work is required
Dirt in the motor cabinet
Distinctive changes in the behavior of the machine
Unusual sounds emitted by the machine
Problems with positioning accuracy
Higher current consumption
Maintenance
9.2Inspection and maintenance
Naturally-Cooled 1FN3 Linear Motors
Operating Instructions, 06/2023, A5E52220465B AB 113