4.2.3 Storage
Storing indoors
Apply a preservation agent (e.g.Tectyl) to bare external motor components if this has not
already been carried out in the factory.
Store the motors as described in Section "Ambient conditions for long-term storage and
transport". The storage room/area must meet the following conditions:
Dry
Dust-free
Free of vibration
Well ventilated
Protected against extreme weather conditions
The air inside the room or space must be free of any aggressive gases
Protect the motor against shocks and humidity.
Make sure that the motor is covered properly.
Protection against humidity
If a dry storage area is not available, then take the following precautions:
Wrap the motor in humidity-absorbent material. Then wrap it in foil so that it is air tight.
Include several bags of desiccant in the sealed packaging. Check the desiccant and replace
it as required.
Place a humidity meter in the sealed packaging to indicate the level of air humidity inside it.
Inspect the motor on a regular basis.
Preparations for use
4.2Transporting and storage
Naturally-Cooled 1FN3 Linear Motors
56 Operating Instructions, 06/2023, A5E52220465B AB

Table of Contents

Other manuals for Siemens SIMOTICS L-1FN3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS L-1FN3 and is the answer not in the manual?

Siemens SIMOTICS L-1FN3 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS L-1FN3
CategoryEngine
LanguageEnglish

Related product manuals