Supplementary system components
6.3 TB30 terminal board
SIMOTION D4x5-2
90 Manual, 11/2010
Note
With momentary interruptions in the 24 V supply, the digital outputs are deactivated during
this time.
6.3.3.5 Analog inputs and outputs
Table 6- 7 Terminal block X482
Terminal Designation
1)
Technical specifications
1 AI 0+
2 AI 0-
3 AI 1+
4 AI 1-
Analog inputs (AI):
Voltage: -10 V to +10 V
Internal resistance: 65 kΩ
Resolution: 13 bits + sign
5 AO 0+
6 AO 0-
7 AO 1+
8 AO 1-
Analog outputs (AO):
Voltage range: -10 V to +10 V
Load current: max. -3 mA to +3 mA
Resolution: 11 bits + sign
Sustained short-circuit strength
Table 6- 8 X482 wiring
Characteristics Type
Connectable cable types
Rigid
Flexible
Flexible, with wire-end ferrule without plastic sleeve
AWG / kcmil
Conductor cross-sections
0.14 mm
2
to 0.5 mm
2
0.14 mm
2
to 0.5 mm
2
0.25 mm
2
to 0.5 mm
2
26 to 20
Stripped length 8 to 9 mm
Tool Screwdriver 0.4 x 2.0 mm
Note
An open input is interpreted as approximately "0 V".
The power supply of the analog inputs/outputs of the TB30 is via the option slot of the
D4x5-2 control unit and not via X424.
The shield is connected to the control unit. For further information on "Creating a shield
connection", see
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual,
Section "Connecting".