EasyManuals Logo

Siemens SIMOTION D410-2 DP User Manual

Siemens SIMOTION D410-2 DP
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #257 background imageLoading...
Page #257 background image
Return values:
16#00000000: Function performed without errors.
16#FFFF8091: Functionality is not supported for the device.
If the restart was triggered by the system function _restart, the following entry is made in the
diagnostic buffer: The SIMOTION device has been switched to STOP and restarted by the
user program using the _restart system function.
The user program must ensure that, when the D410‑2 restarts, no axis movements or other
unwanted influences on the machine by the user program occur.
If an error occurs after the automatic restart, there is not special error handling for this case.
If this error prevents startup, the SIMOTION device cannot enter the RUN state. An error during
startup does not trigger an automatic restart.
Commissioning (software)
7.22 Special functions SIMOTION D410-2
SIMOTION D410-2
Commissioning and Hardware Installation Manual, 01/2015 257