2.4 Commissioning software
Requirement
To
create and edit projects on your PG/PC, you need the SIMOTION SCOUT commissioning
and configuration tool.
For information on how to install SIMOTION SCOUT, see the
SIMOTION SCOUT
Configuration Manual.
Note
SIMOTION SCOUT contains the functionality of STARTER and SIMATIC S7-Technology.
Simultaneous operation of SIMOTION SCOUT, STARTER and SIMATIC S7-Technology as
a single installation on one PG/PC is not possible.
Integrated STARTER
You can insert a standalone drive (e.g. SINAMICS S120) with the "Insert single drive unit"
element in the project navigator. It is commissioned using wizards in the working area of the
workbench that contains the STARTER functionality.
SINAMICS Support Package (SSP)
The following SSPs are relevant for SIMOTION SCOUT:
●
SSP "SINAMICS" for single drive units (e.g. CU3xx)
● "SIMOTION SINAMICS Integrated" SSP for the SINAMICS drive integrated into
SIMOTION D410‑2.
You will find detailed information on the SSPs in the readme files and in the software
compatibility list at Internet address (
http://support.automation.siemens.com/WW/view/en/
18857317).
Upgrading SIMOTION D410‑2 projects and hardware
Projects that you have created for one SIMOTION D410‑2 firmware version can also be
converted for other firmware versions. See, for example, Section
Service and maintenance
(Page 259).
SIMOTION IT web server
The SIMOTION D410‑2 features an integrated web server.
The web server supports the display of diagnostics and system data in standard Internet
browsers, even in the absence of an engineering system, and the carrying out of project/
firmware updates.
Description
2.4 Commissioning software
SIMOTION D410-2
34 Commissioning and Hardware Installation Manual, 01/2015