7.21 Migration from SIMOTION D410 to SIMOTION D410-2
7.21.1
Upgrade from SIMOTION D410 to SIMOTION D410-2
SIMOTION D410-2 differs both in the structure and in the functionality of a SIMOTION D410.
This has effects that must be taken into account during a changeover.
Change from D410 to D410-2 (upgrade)
The change from SIMOTION D410 to SIMOTION D410‑2 is performed with a module
replacement in HW Config. The procedure when changing is similar to that when changing,
for example, from SIMOTION D445-2 DP/PN to SIMOTION D455-2 DP/PN.
The module replacement is started by dragging the new module to the frame of the module
rack with the existing module in HW Config, see Section Device replacement in HW Config
(Page 275).
The module replacement is performed automatically. During this operation, the technology
packages and the device versions are updated. Existing configurations of the SIMOTION D410
are transferred to the SIMOTION D410‑2 during the module replacement.
Information on where project adaptations are required or not required when changing from a
SIMOTION D410 to a SIMOTION D410‑2 can be found in the following sections (see Table
"Transfer of existing SIMOTION D410 projects to SIMOTION D410‑2").
For further information on generally required measures for project adaptations, see Section
Service and maintenance (Page 259).
Change from D410‑2 to D410 (downgrade)
As a SINAMICS drive cannot be downgraded, a module replacement of a SIMOTION D410‑2
(SINAMICS Integrated firmware V4.x) with a SIMOTION D410 (SINAMICS Integrated firmware
V2.x) is not possible.
However, project data can be transferred by means of an XML export/import.
Transfer of existing projects
Existing configurations of the SIMOTION D410 are transferred to the SIMOTION D410‑2
during the module replacement.
Commissioning (software)
7.21 Migration from SIMOTION D410 to SIMOTION D410-2
SIMOTION D410-2
250 Commissioning and Hardware Installation Manual, 01/2015

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D410-2 DP and is the answer not in the manual?

Siemens SIMOTION D410-2 DP Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D410-2 DP
CategoryController
LanguageEnglish

Related product manuals