Advanced commissioning
7.6 Basic positioner and position control
Converter with control units CU250D-2
206 Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
Table 7- 19 Job and parameters
Positioning ---
• Axis absolute or relative positioning.
• Rotary axis with modulo correction in a positive or
negative direction, absolute positioning.
Travel to fixed
stop
Force [N] or torque
[0.01 Nm]
Traverse axis to a fixed stop:
• Linear axis with reduced force.
• Rotary axis with reduced torque.
See also the section: Travel to fixed stop (Page 213).
Endless travel --- Traverse the axis at the specified velocity to the posi-
tive or negative end of the traversing range.
Wait Time [ms] Wait the specified time.
Go to Number The converter then executes the next traversing block
with the specified number.
Set, reset
Set or reset internal signals in the converter:
• Output 1: r2683.10
• Output 2: r2683.11
You can interconnect the signals with digital outputs of
the converter or with bit 10 and 11 of the positioning
status word of the fieldbus.
See also the sections: Control and status word for the
positioner (Page 94) , Control and status word 2 for the
3 Set outputs 1 and
2
Jerk
Activate or deactivate jerk limiting.
See also the section: Limiting the traversing profile
1 active