9.5.3 Replacing the operator panel
Power supply
Communication cable
Retaining lug
Figure 9-11 Replacing the operator panel
To replace the operator panel, proceed as follows:
1. Switch off the main circuit-breaker.
2. Open the cabinet.
3. Disconnect the power supply and communication cable at the operator panel.
4. Press the retaining lugs and withdraw the operator panel to the front.
5. Snap on a new operator panel.
6. Attach the connectors for the power supply and communications cable.