the braking resistor with a temperature monitoring. Wire the temperature monitoring so that the
drive shuts down when triggered.
The braking resistor and cabling are required to meet the following requirements in relation to
inductance L:
The time constant L/R must not exceed the value 20 µs. L must be smaller than R x 20 μs.
Note
The signal cable to the temperature monitor and the power cable are not included in the scope
of supply.
See also
Braking Module (option L72) (Page 52)
Description
3.6 Description of options
SINAMICS GM150 6SL3810-2LN31-8AA2
56 Operating Instructions Rev.201910281332 EXAMPLE