Communication via PROFIBUS DP
4.4 Slave-to-slave communication
Communication
Function Manual, 12/2018, 6SL3097-5BD00-0BP0
101
Parameterizing telegram (SetPrm)
The filter table is transferred, as dedicated block from the master to the slave with the
parameterizing telegram when a bus communication is established.
Figure 4-9 Filter block in the parameterizing telegram (SetPrm)
Configuration telegram (ChkCfg)
Using the configuration telegram, a slave knows how many setpoints are to be received from
the master and how many actual values are to be sent to the master.
For slave-to-slave communication, a special space ID is required for each tap. The
PROFIBUS configuration tool (e.g. HW Config) generates this ID. The ID is then transferred
with the ChkCfg into the drive devices that operate as subscribers.