Communication according to PROFIdrive
3.5 Diagnostics channels
Communication
Function Manual, 12/2018, 6SL3097-5BD00-0BP0
67
3.5.1 PROFINET-based diagnostics
For PROFINET, to transfer PROFIdrive message classes, channel diagnostics (Channel
Diagnosis) are used (see PROFINET IO specification (http://www.profibus.com)).
A message always comprises the following components in this specific sequence:
Block Header (6 Byte)
Blocktype
Blocklength
BlockversionHigh
BlockversionLow
API (4 Byte)
Slot Number (2 Byte)
Sub Slot Number (2 Byte)
Channel Number (2 Byte)
Channel Properties (0x8000) (2 Byte)
User Structure Identifier (2 Byte)
Channel Diagnosis Data (6 Byte)
Channel Number (2 Byte)
Channel Properties (2 Byte)
Channel Error Type (2 Byte)
Overview:
Figure 3-9 Components of a message

Table of Contents