Communication
Function Manual, 12/2018, 6SL3097-5BD00-0BP0
183
Communication via Ethernet/IP (EIP)
7
7.1 Overview
EtherNet/IP (EIP) is a realtime Ethernet, and is mainly used in automation technology.
The EtherNet Industrial Protocol (EtherNet/IP) is an open standard for industrial networks.
EtherNet/IP is used to transmit cyclic I/O data and acyclic parameter data. EtherNet/IP was
developed by Rockwell Automation and the Open Device-Net Vendor Association (ODVA
(https://www.odva.org/Technology-Standards/EtherNet-IP/Overview)), and standardized in
the series of international IEC 61158 standards. EtherNet/IP uses the basis technology of
Ethernet TCP/IP, which has been well proven in practice. Ethernet twisted-pair cables or
fiber-optic cables are used as data transmission medium. The CIP protocol (Common
Industrial Protocol) known from DeviceNet and ControlNet is used as application
protocol.
General information about communication
Communication via EIP requires the following interfaces:
The Ethernet interface (X1400) of the Ethernet CBE20 option board
The onboard PROFINET interface (X150) at the CU320-2 PN and CU310-2 PN Control
Units
The interfaces are either individually available at the different Control Units, or together at
one Control Unit (e.g. at a CU320-2 PN with CBE20).
The following table provides an overview of the configurable Control Units and interfaces that
are available for communication via EIP.
Table 7- 1 Configurable Control Units and interfaces
Control Unit
EIP via X150
EIP via X1400 (CBE20)
CU320-2 PN Yes No
CU320-2 PN with CBE20 (optional)
Yes
Yes
CU310-2 PN
Yes
No
CU320-2 DP
with CBE20
No
Yes
Independent of the configuration, only one interface can be assigned for communication via
EIP. A simultaneous connection via the interfaces X150 and X1400 is not possible and is
acknowledged with alarm A08555(1).