Communication via Ethernet/IP (EIP)
7.6 Supported objects
Communication
Function Manual, 12/2018, 6SL3097-5BD00-0BP0
189
Table 7- 4 Instance Attribute
2 get UINT16 Device Type
- Siemens Drive
0C hex
4 get UINT16 Revision -
6 get UINT32 Serial number Bit 0 … 19: consecutive number;
bits 20 … 23: Production identifier
bits 24 … 27: Month of manufacture (0 = Jan, B =
Dec)
Bits 28 … 31: Year of manufacture (0 = 2002)
7 get Short
Product name max. length 32 byte
Table 7- 5 Explanation for No. 5 of the previous table
1 0 Owned 0: Converter is not assigned to a controller
1: Converter is assigned to a controller
2 Configured 0: Ethernet/IP basic settings
1: Modified Ethernet/IP settings
4 … 7 Extended De-
vice Status
0: Self-test or status not known
1: Firmware update active
2: At least one I/O connection with error
3: No I/O connections
4: Incorrect configuration in the ROM
5: Fatal fault
6: At least one I/O connection is active
7: All I/O connections in the quiescent state