Communication via Ethernet/IP (EIP)
7.6 Supported objects
Communication
Function Manual, 12/2018, 6SL3097-5BD00-0BP0
191
Connection Management Object, Instance Number: 6 hex
Supported services
Class
Get Attribute all
Get Attribute single
Instance
Forward open
Forward close
Get Attribute single
Set Attribute single
Table 7- 8 Class Attribute
No.
Service
Type
Name
1
get
UINT16
Revision
2
get
UINT16
Max Instance
3
get
UINT16
Num of Instances
Table 7- 9 Instance Attribute
No.
Service
Type
Name
Value/explanation
1
get
UINT16
OpenReqs
Counters
2
get
UINT16
OpenFormat Rejects
Counters
3
get
UINT16
OpenResource Rejects
Counters
4
get
UINT16
OpenOther Rejects
Counters
5
get
UINT16
CloseReqs
Counters
6
get
UINT16
CloseFormat Rejects
Counters
7 get UINT16 CloseOther Rejects Counters
8 get UINT16 ConnTimeouts
Counters
Number of bus errors