Communication via PROFIBUS
Acyclic communication
4-128
E Siemens AG, 2004. All rights reserved
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
Table 4-17 Error values in DPV1 parameter responses, continued
Error
value
Add.
informa-
tion
CommentsMeaning
0x65 Presently deactivated You have tried to access a parameter that,
although available, is currently inactive (e.g. n
control set and access to parameter from V/f
control).
-
0x68 Illegal value Modification request with a value that,
although within limits, is impermissible for
other reasons (e.g. parameter with defined
individual values).
-
0x6B Parameter %s [%s]: No write
access for the enabled controller
- -
0x6C Parameter %s [%s]: Unit unknown - -
0x6D Parameter %s [%s]: write access
only in the commissioning state,
encoder (p0010 = 4).
- -
0x6E Parameter %s [%s]: write access
only in the commissioning state,
motor (p0010 = 3).
- -
0x6F Parameter %s [%s]: write access
only in the commissioning state,
Power Module (p0010 = 2).
- -
0x70 Parameter %s [%s]: write access
only in fast commissioning state
(p0010 = 1).
- -
0x71 Parameter %s [%s]: write access
only in the ready state
(p0010 = 0).
- -
0x72 Parameter %s [%s]: write access
only in the commissioning state,
parameter reset (p0010 = 30).
- -
0x73 Parameter %s [%s]: write access
only in the commissioning state,
Safety (p0010 = 95).
- -
0x74 Parameter %s [%s]: write access
only in the commissioning state,
technological application/units
(p0010 = 5).
- -
0x75 Parameter %s [%s]: write access
only in the commissioning state
(p0010 not equal to 0).
- -
0x76 Parameter %s [%s]: write access
only in the commissioning state,
download (p0010 = 29).
- -
0x77 Parameter %s [%s] may not be
written in download.
- -