Basic Information about the Drive System
BICO technology: interconnection of signals
7-242
E Siemens AG, 2004. All rights reserved
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
Signals for the analog outputs
Table 7-4 List of signals for analog outputs
Signal
Parameter Unit Scaling
(100% = ...)
Speed setpoint before
setpoint filter
r0060 1/min p2000
Speed actual value
motor encoder
r0061 1/min p2000
Actual speed smoothed r0063 1/min p2000
Drive output frequency r0066 Hz Reference frequency
Absolute current actual
value
r0068 Aeff p2002
Actual DC link voltage r0070 V p2001
Torque setpoint total r0079 Nm p2003
Actual active power r0082 kW r2004
Control deviation r0064 1/min p2000
Modulat_depth r0074 % Reference control factor
Current setpoint,
torque-generating
r0077 A p2002
Current actual value,
torque-generating
r0078 A p2002
Flux setpoint r0083 % Reference flux
Actual flux r0084 % Reference flux
Speed controller PI
torque output
r1480 Nm p2003
Speed controller I torque
output
r1482 Nm p2003