Cycles
9.8 Plunge-cutting - CYCLE410
Cylindrical grinding
174 Programming and Operating Manual, 07/2009, 6FC5398-4CP10-2BA0
TIME (sparking-out time)
After reaching the workpiece finished dimension, the tool dwells at the end position for a
defined time. This time is called 'sparking-out time'. It is programmed in [s].
MZ (measurement control)
The MZ parameter is used to specify whether a measurement control is used.
0 = No measurement control
1 = With measurement control
KS (acoustic emission sensor)
The KS parameter is used to specify whether an acoustic emission sensor is used.
0 = without acoustic emission sensor
1= with acoustic emission sensor
F_KS (feedrate for air grinding)
With an air grinding feedrate, the path between the starting point and the point where the
wheel comes into contact with the workpiece (with the aid of the acoustic emission sensor) is
traversed.
OSW (reciprocation travel)
;
=
26:
During plunge-cut grinding, this parameter can be used to activate a short-travel
reciprocation. Starting point is the position under Z_ST. It is programmed in [mm].
UWERK
Use the UWERK parameter to specify the peripheral speed of the workpiece in m/min.

Table of Contents

Other manuals for Siemens SINUMERIK 802D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 802D and is the answer not in the manual?

Siemens SINUMERIK 802D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 802D
CategoryControl Unit
LanguageEnglish

Related product manuals