EasyManuals Logo
Home>Siemens>Control Unit>SINUMERIK 802D

Siemens SINUMERIK 802D User Manual

Siemens SINUMERIK 802D
399 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #319 background imageLoading...
Page #319 background image
Programming
10.12 Timers and workpiece counters
Cylindrical grinding
Programming and Operating Manual, 07/2009, 6FC5398-4CP10-2BA0
319
10.12 Timers and workpiece counters
10.12.1 Runtime timer
Functionality
The timers are prepared as system variables ($A...) that can be used for monitoring the
technological processes in the program or only in the display.
These timers are read-only. There are timers that are always active. Others can be
deactivated via machine data.
Timers - always active
$AN_SETUP_TIME
Time since the last control powerup with default values (in minutes)
It is automatically reset in the case of a "Control power-up with default values".
$AN_POWERON_TIME
Time since the last control powerup (in minutes)
It is reset to zero automatically with each power-up of the control system.
Timers that can be deactivated
The following timers are activated via machine data (default setting).
The start is timer-specific. Each active run-time measurement is automatically interrupted in
the stopped program state or for feedrate-override-zero.
The behavior of the activated timers for active dry run feedrate and program testing can be
specified using machine data.

Table of Contents

Other manuals for Siemens SINUMERIK 802D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 802D and is the answer not in the manual?

Siemens SINUMERIK 802D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 802D
CategoryControl Unit
LanguageEnglish

Related product manuals