Table of contents
Guide for the SINUMERIK 840D sl machine configuring
vi Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0
3.3 Macros for commissioning ......................................................................................................... 3-2
3.4 Procedure for calling ACX macros............................................................................................. 3-4
3.5 X122 and X132 Interface Overview ...........................................................................................3-6
3.6 NCU 7x0 and NX1x Terminal Assignment................................................................................. 3-9
4 Safety Integrated .................................................................................................................................... 4-1
4.1 SINAMICS Safety Integrated ..................................................................................................... 4-1
4.1.1 Control of the "Safe Standstill" Safety Function.........................................................................4-1
4.1.2 Safe Brake Control (SBC).......................................................................................................... 4-8
4.2 SINUMERIK Safety Integrated................................................................................................... 4-9
4.2.1 Fundamentals ............................................................................................................................ 4-9
4.2.2 Connection to Monitoring Channels........................................................................................... 4-9
5 Connection of the Components .............................................................................................................. 5-1
5.1 Power Supply Interface Variants................................................................................................ 5-1
5.1.1 Ways of connecting the line supply............................................................................................ 5-1
5.1.2 Operation of the line connection components on the supply network ....................................... 5-2
5.1.3 Operating line connection components via an autotransformer ................................................ 5-3
5.1.4 Operating line connection components via an isolating transformer ......................................... 5-4
5.1.5 Line connection via a ground-fault circuit interrupter ................................................................. 5-5
5.2 Line Contactor Control ............................................................................................................... 5-8
5.2.1 Line Contactor Control for Line Modules without DRIVE-CLiQ Interface .................................. 5-8
5.2.2 Line Contactor Control for Line Modules with DRIVE-CLiQ Interface ..................................... 5-10
5.2.3 Line Contactor Control Commissioning using an Example...................................................... 5-10
5.3 Line Modules Interfaces Description........................................................................................ 5-13
5.3.1 Line Modules Overview............................................................................................................ 5-13
5.3.2 Active Line Modules with Internal Air Cooling.......................................................................... 5-16
5.3.2.1 Overview .................................................................................................................................. 5-16
5.3.2.2 Connection example ................................................................................................................ 5-17
5.3.2.3 X1 line connection.....................................
............................................................................... 5-18
5.3.2.4 Active Line Module X21 EP Terminals..................................................................................... 5-19
5.3.2.5 Active Line Module X24 24 V Terminal Adapter ...................................................................... 5-20
5.3.2.6 X200-X202 DRIVE-CLiQ interfaces ......................................................................................... 5-21
5.3.2.7 24 V busbar.............................................................................................................................. 5-21
5.3.2.8 Active Line Module DC Link Busbar ........................................................................................ 5-21
5.3.2.9 Meaning of the LEDs on the Active Line Module..................................................................... 5-22
5.3.3 Smart Line Modules (5 kW und 10 kW) with internal air cooling ............................................. 5-23
5.3.3.1 Overview .................................................................................................................................. 5-23
5.3.3.2 Connection example ................................................................................................................ 5-24
5.3.3.3 X1 line connection.................................................................................................................... 5-25
5.3.3.4 X21 terminals: smart line module............................................................................................. 5-25
5.3.3.5 X22 terminals: smart line module............................................................................................. 5-27
5.3.3.6 X24 24 V terminal adapter ....................................................................................................... 5-28
5.3.3.7 24 V busbar.............................................................................................................................. 5-28
5.3.3.8 Smart Line Module DC Link Busbar......................................................................................... 5-29
5.3.3.9 Meaning of the LEDs on the Smart Line Module ..................................................................... 5-29
5.4 Motor Modules Interface Description ....................................................................................... 5-30
5.4.1 Overview .................................................................................................................................. 5-30
5.4.2 Connection Examples .............................................................................................................. 5-31
5.4.3 Motor/brake connection............................................................................................................ 5-32
5.4.4 X21/X22 EP Terminals / Motor Module Temperature Sensor Connection .............................. 5-34
5.4.5 X200-X203 DRIVE-CLiQ interface........................................................................................... 5-36

Table of Contents

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120
Data StorageCF card, USB
Operating SystemWindows-based